欢迎光临散文网 会员登陆 & 注册

COPPUS JECTAIR HP AND HORNET HP

2023-02-16 08:00 作者:苏州敦品工业陈明鹏  | 我要投稿

COPPUS JECTAIR® HP AND HORNET HP

High-Performance, Highly Efficient Venturi Air Movers

The unmatched performance of the COPPUS Jectair® HP is recognized throughout the industry. When compared with older-style air horns, the patented air mixing chamber of the Jectair® HP can produce up to a 40:1 air flow conversion and up to 26 percent savings on compressed air consumption.

Operating Principle: Compressed air or steam is admitted into the Jectair through a single inlet connection in the housing leading to the mixing chamber. The air or steam jetted from the nozzle creates a “Venturi” action that induces a large volume of surrounding air to enter the Jectair through the aerodynamic inlet bell. The air is then discharged at high velocity through the horn-shaped diffuser.

Note: Operating efficiency depends on compressed air volume and pressure (see charts)

 

FEATURES & ADVANTAGES: (JECTAIR)

  • Standard Jectair in five sizes: 3SHP, 3HP, 6HP, 8, or 9

  • Heavy-gauge steel diffusers; aluminum diffusers available on 3HP & 6HP model

  • Compressed air or steam operated

  • Air flows range from 1,370 to 8,900 cfm (2,328 to 15,121 m3/hr)

  • Induction ratios up to 40:1

  • Multiple expansion nozzles machined into housing

  • High static pressure capabilities

  • No moving parts; virtually maintenance free

  • Static bonding cable with spring tension grip and replaceable contact tips.

  • Easily attach duct to outlet diffuser end

  • Inlet duct adapter available (optional)

  • Tripod for stationary mounting available (optional)

 

FEATURES & ADVANTAGES: (HORNET HP)

  • Hornet HP models available in three sizes: 3SHP, 3HP, & 6HP

  • Features a lightweight, shock-resistant, conductive polymer diffuser that is virtually indestructible

  • Polymer safely dissipates static electricity charges

  • Diffuser is constructed of linear low-density polyethylene

  • UL 94 rating with maximum operating temperature of 160°F (93°C)

  • Compressed air operated only

  • Air flows range from 1,370 to 8,900 cfm (2,328 to 15,121 m3/hr)

  • Induction ratios up to 40:1

  • Multiple expansion nozzles machined into housing

  • High static pressure capabilities

  • No moving parts; virtually maintenance free

  • Static bonding cable with spring tension grip and replaceable contact tips.

  • Easily attach duct to outlet diffuser end

  • Inlet duct adapter available (optional)

  • Tripod for stationary mounting available (optional)

 

SAFETY PRECAUTIONS:

  • Use bonding cables when operating in hazardous locations to prevent static electricity discharges

  • Secure unit before admitting compressed air (or steam) to prevent damage or injury from high-reaction force

  • Do not allow solid objects or debris to enter inlet housing during operation

  • When exhausting fumes from an enclosed vessel, take care not to create a vacuum that could collapse the vessel

 

ACCESSORIES:

  • Inlet Duct Adapter (3SHP, 3HP, 6HP, 8 & 9)

  • Pipeline Adapter (3HP & 6HP)

  • Tripod Stands (3SHP, 3HP & 6HP)

  • Filter Sock (6HP only)

  • Duct (8” Heavy duty, Conductive or Polyvinyl – 3SHP & 3HP)

  • Duct (12” Heavy duty, Conductive or Polyvinyl – 6HP)

  • Duct (16” Heavy duty, Conductive or Polyvinyl – 8 & 9)

  • Duct Canisters (8”, 12” & 16”)

 

DIMENSIONS:


PHYSICAL DIMENSIONS

 

PERFORMANCE:

 

EFFICIENCY:

 

NOISE: