PCD235B1101 ABB板 3BHE032025R1101 检查当前配置的流量范围
PCD235B1101 3BHE032025R1101
PCD232A101 3BHE022293R0101
PCD231B101 3BHE025541R0101
对于全新系统或初始启动
•流量计传感器的校准数据和变送器设置从
SensorMemory1)输入变送器。
更换完整的变送器或变送器电子单元后
•用“变送器”进行选择。流量计传感器的校准数据和
变送器设置从传感器存储器1)加载到变送器中。
更换传感器后
•使用“传感器”进行选择。流量计传感器和变送器的校准数据
设置从传感器存储器1)加载到变送器中。变送器设置
存储在传感器存储器中1)。如果新传感器的尺寸不同,请检查当前
配置的流量范围。
3.流量计已准备好运行,并将在出厂设置或设置的情况下运行
客户要求。要更改出厂设置,请参阅第章
7“参数化”。
1) SensorMemory是集成在流量计传感器中的数据存储器。
重要(通知)
系统数据只能在初始启动期间加载。如果电源随后被切断,
发射器在下一次打开时再次自动加载数据。
不需要进行如下所述的选择(1-3)。
以下适用于小型设备:
(变送器直接安装在流量计传感器上)
•在10。。。58赫兹范围,最大0.15毫米(0.006英寸)
偏转
•在58。。。150 Hz范围,最大加速度为2 g
以下适用于带有单独变送器的设备:
变送器
•在10。。。58赫兹范围,最大0.15毫米(0.006英寸)
偏转
•在58。。。150 Hz范围,最大加速度为2 g
流量计传感器
•在10。。。58赫兹范围,最大0.15毫米(0.006英寸)
偏转
•在58。。。150 Hz范围,最大加速度为2 g




For a completely new system or initial startup
• The calibration data of the flowmeter sensor and the transmitter settings are loaded from the
SensorMemory1) into the transmitter.
After replacing the complete transmitter or transmitter electronic unit
• Select with “Transmitter”. The calibration data of the flowmeter sensor and the
transmitter settings are loaded from the SensorMemory1) into the transmitter.
After replacing the sensor
• Select with “Sensor”. The calibration data of the flowmeter sensor and the transmitter
settings are loaded from the SensorMemory1) into the transmitter. The transmitter settings
are stored in the SensorMemory1). If the new sensor is a different size, check the currently
configured flow range.
3. The flowmeter is ready for operation and will operate with factory settings or settings
requested by the customer. To change the factory settings, refer to chapter
7 "Parameterization".
1) The SensorMemory is a data memory integrated in the flowmeter sensor.
Important (Notice)
System data must only be loaded during initial startup. If the supply power is later switched off,
the transmitter automatically loads the data once again the next time it is switched on.
A selection as described below (1-3) is not required.
The following applies to compact devices:
(transmitter mounted directly on the flowmeter sensor)
• In the 10 ... 58 Hz range with max. 0.15 mm (0.006 inch)
deflection
• In the 58 ... 150 Hz range with max. 2 g acceleration
The following applies to devices with a separate transmitter:
Transmitter
• In the 10 ... 58 Hz range with max. 0.15 mm (0.006 inch)
deflection
• In the 58 ... 150 Hz range with max. 2 g acceleration
Flowmeter sensor
• In the 10 ... 58 Hz range with max. 0.15 mm (0.006 inch)
deflection
• In the 58 ... 150 Hz range with max. 2 g acceleration