[VPLEX]在两台Local之间做数据迁移
说明:
VPLEX不支持跨独立VPLEX群集的XCopy。
VPLEX只支持在Metro配置中夸两个集群的XCopy。
解决问题:
1. 在VPLEX上禁用storage-view的XCopy
2. 在ESXi主机上启用加速锁定(可选)
解决方法:
1. 通过SSH登录到VPLEX,进入vplexcli模式下,将目录切换到/clusters/cluster-1/exports/storage-views下查看storage-view
VPlexcli:/> cd /clusters/cluster-1/exports/storage-views/
VPlexcli:/clusters/cluster-1/exports/storage-views> ls
VMware
进入你的storage-view,并执行关闭XCopy命令
VPlexcli:/clusters/cluster-1/exports/storage-views> cd VMware/
VPlexcli:/clusters/cluster-1/exports/storage-views/VMware> set xcopy-enabled false
查看更改效果:
VPlexcli:/clusters/cluster-1/exports/storage-views/VMware> ll
Name Value
------------------------ ---------------------------------------------------------------------------------------
caw-enabled true
controller-tag -
initiators ESXi1821041_2, ESXi1821041_3, ESXi1821042_2, ESXi1821042_3, ESXi1821061_2,
ESXi1821061_3, ESXi1821062_2, ESXi1821062_3, ESXi1821063_2, ESXi1821063_3, ... (104
total)
operational-status ok
port-name-enabled-status P0000000047A03A92-A0-FC00,true,ok, P0000000047A03A92-A0-FC01,true,ok,
P0000000047A03A92-A0-FC02,true,ok, P0000000047A03A92-A0-FC03,true,ok,
P0000000047A03B8E-A0-FC00,true,ok, P0000000047A03B8E-A0-FC01,true,ok,
P0000000047A03B8E-A0-FC02,true,ok, P0000000047A03B8E-A0-FC03,true,ok,
P0000000047B03A92-B0-FC00,true,ok, P0000000047B03A92-B0-FC01,true,ok, ... (16 total)
ports P0000000047A03A92-A0-FC00, P0000000047A03A92-A0-FC01, P0000000047A03A92-A0-FC02,
P0000000047A03A92-A0-FC03, P0000000047A03B8E-A0-FC00, P0000000047A03B8E-A0-FC01,
P0000000047A03B8E-A0-FC02, P0000000047A03B8E-A0-FC03, P0000000047B03A92-B0-FC00,
P0000000047B03A92-B0-FC01, ... (16 total)
virtual-volumes (0,device_CLARiiON0109_Y_VNX_LUN_27_1_vol,VPD83T3:6000144000000010b03a92b11c792c7a,3T),
(1,device_CLARiiON0109_Y_VNX_LUN_26_1_vol,VPD83T3:6000144000000010b03a92b11c792c79,3T), (2,device_CLARiiON0109_Y_VNX_LUN_25_1_vol,VPD83T3:6000144000000010b03a92b11c792c78,3T), (3,device_CLARiiON0109_Y_VNX_LUN_24_1_vol,VPD83T3:6000144000000010b03a92b11c792c77,3T), (4,device_CLARiiON0109_Y_VNX_LUN_23_1_vol,VPD83T3:6000144000000010b03a92b11c792c76,3T), (5,device_CLARiiON0109_Y_VNX_LUN_22_1_vol,VPD83T3:6000144000000010b03a92b11c792c75,3T), (6,device_CLARiiON0109_Y_VNX_LUN_21_1_vol,VPD83T3:6000144000000010b03a92b11c792c74,3T), (7,device_CLARiiON0109_Y_VNX_LUN_20_1_vol,VPD83T3:6000144000000010b03a92b11c792c73,3T), (8,device_CLARiiON0109_Y_VNX_LUN_19_1_vol,VPD83T3:6000144000000010b03a92b11c792c72,3T), (9,device_CLARiiON0109_Y_VNX_LUN_18_1_vol,VPD83T3:6000144000000010b03a92b11c792c71,3T),
... (57 total)
write-same-16-enabled true
xcopy-enabled false
最后一行显示已经关闭。
注:两台VPLEX Local都需要修改
2. 在受影响的ESXi主机上,启用加速锁定但禁用加速移动(XCOPY)。
用户可以选择性地禁用ESXi主机上不支持的基元,而不是禁用VAAI中的所有内容。 要更具体地了解这些变化:
HardwareAcceleratedLocking = OK; enable (atomic test and set)
HardwareAcceleratedMove = Not OK; leave disabled (clone blocks, full copy, xcopy)
HardwareAcceleratedInit = OK; enable (zero blocks, write same)