欢迎光临散文网 会员登陆 & 注册

[VPLEX]在两台Local之间做数据迁移

2023-02-16 23:30 作者:墨小胎  | 我要投稿

说明:

VPLEX不支持跨独立VPLEX群集的XCopy。

VPLEX只支持在Metro配置中夸两个集群的XCopy。

 

解决问题:

1.      在VPLEX上禁用storage-view的XCopy

2.      在ESXi主机上启用加速锁定(可选)

 

解决方法:

1.      通过SSH登录到VPLEX,进入vplexcli模式下,将目录切换到/clusters/cluster-1/exports/storage-views下查看storage-view

VPlexcli:/> cd /clusters/cluster-1/exports/storage-views/                                                                         

VPlexcli:/clusters/cluster-1/exports/storage-views> ls                                                                            

VMware

进入你的storage-view,并执行关闭XCopy命令

VPlexcli:/clusters/cluster-1/exports/storage-views> cd VMware/                                                                    

VPlexcli:/clusters/cluster-1/exports/storage-views/VMware> set xcopy-enabled false     

 

查看更改效果:

VPlexcli:/clusters/cluster-1/exports/storage-views/VMware> ll                                                                     

Name                      Value

------------------------  ---------------------------------------------------------------------------------------

caw-enabled               true

controller-tag            -

initiators                ESXi1821041_2, ESXi1821041_3, ESXi1821042_2, ESXi1821042_3, ESXi1821061_2,

                          ESXi1821061_3, ESXi1821062_2, ESXi1821062_3, ESXi1821063_2, ESXi1821063_3, ... (104

                          total)

operational-status        ok

port-name-enabled-status  P0000000047A03A92-A0-FC00,true,ok, P0000000047A03A92-A0-FC01,true,ok,

                          P0000000047A03A92-A0-FC02,true,ok, P0000000047A03A92-A0-FC03,true,ok,

                          P0000000047A03B8E-A0-FC00,true,ok, P0000000047A03B8E-A0-FC01,true,ok,

                          P0000000047A03B8E-A0-FC02,true,ok, P0000000047A03B8E-A0-FC03,true,ok,

                          P0000000047B03A92-B0-FC00,true,ok, P0000000047B03A92-B0-FC01,true,ok, ... (16 total)

ports                     P0000000047A03A92-A0-FC00, P0000000047A03A92-A0-FC01, P0000000047A03A92-A0-FC02,

                          P0000000047A03A92-A0-FC03, P0000000047A03B8E-A0-FC00, P0000000047A03B8E-A0-FC01,

                          P0000000047A03B8E-A0-FC02, P0000000047A03B8E-A0-FC03, P0000000047B03A92-B0-FC00,

                          P0000000047B03A92-B0-FC01, ... (16 total)

virtual-volumes           (0,device_CLARiiON0109_Y_VNX_LUN_27_1_vol,VPD83T3:6000144000000010b03a92b11c792c7a,3T),

                          (1,device_CLARiiON0109_Y_VNX_LUN_26_1_vol,VPD83T3:6000144000000010b03a92b11c792c79,3T),                       (2,device_CLARiiON0109_Y_VNX_LUN_25_1_vol,VPD83T3:6000144000000010b03a92b11c792c78,3T), (3,device_CLARiiON0109_Y_VNX_LUN_24_1_vol,VPD83T3:6000144000000010b03a92b11c792c77,3T), (4,device_CLARiiON0109_Y_VNX_LUN_23_1_vol,VPD83T3:6000144000000010b03a92b11c792c76,3T), (5,device_CLARiiON0109_Y_VNX_LUN_22_1_vol,VPD83T3:6000144000000010b03a92b11c792c75,3T), (6,device_CLARiiON0109_Y_VNX_LUN_21_1_vol,VPD83T3:6000144000000010b03a92b11c792c74,3T), (7,device_CLARiiON0109_Y_VNX_LUN_20_1_vol,VPD83T3:6000144000000010b03a92b11c792c73,3T), (8,device_CLARiiON0109_Y_VNX_LUN_19_1_vol,VPD83T3:6000144000000010b03a92b11c792c72,3T), (9,device_CLARiiON0109_Y_VNX_LUN_18_1_vol,VPD83T3:6000144000000010b03a92b11c792c71,3T),

                          ... (57 total)

write-same-16-enabled     true

xcopy-enabled             false

最后一行显示已经关闭。

注:两台VPLEX Local都需要修改

 

2.      在受影响的ESXi主机上,启用加速锁定但禁用加速移动(XCOPY)。

用户可以选择性地禁用ESXi主机上不支持的基元,而不是禁用VAAI中的所有内容。 要更具体地了解这些变化:

HardwareAcceleratedLocking = OK; enable (atomic test and set)
HardwareAcceleratedMove = Not OK; leave disabled (clone blocks, full copy, xcopy)
HardwareAcceleratedInit = OK; enable (zero blocks, write same)

 


[VPLEX]在两台Local之间做数据迁移的评论 (共 条)